Tratamiento de las fracturas en mandíbulas atróficas: nuestra experiencia con la reducción abierta y fijación interna según el principio de carga soportada
Treatment of atrophic mandible fractures: our experience with open reduction and internal fixation according to the load-bearing principle
CIRUGÍA | SERIE DE CASOS | OPEN ACCESS | PEER-REVIEWED
Tratamiento de las fracturas en mandíbulas atróficas: nuestra experiencia con la reducción abierta y fijación interna según el principio de carga soportadaTreatment of atrophic mandible fractures: our experience with open reduction and internal fixation according to the load-bearing principle
Autor/es: Agustín González, Sebastián Berrhau, Mauricio Jaciansky, Sebastián Carella, Carlos Ries Centeno
Vol: 103 | Nº 4 | Dic 2015 | Páginas: 179-186
Presentado: 22/04/2015 | Aceptado: 17/09/2015 | Publicado: 20/12/2015
Stable URL: https://raoa.aoa.org.ar/revistas?roi=1034000184 copiar
Texto completo | PDF | Citar este artículo
Twitter | Whatsapp | Facebook | E-mail
Resumen
Objetivo: Presentar los resultados terapéuticos obtenidos por medio de la reducción abierta y fijación interna, aplicando el principio de carga soportada, en el tratamiento de fracturas de mandíbulas atróficas.
Casos clínicos: Se llevaron a cabo tratamientos en 21 pacientes, con un total de 30 fracturas de mandíbula atrófica, sobre 410 pacientes ingresados por fracturas mandibulares, en un hospital municipal de tercer nivel y en la práctica privada, durante el período 1991-2014.
Conclusión: La reducción abierta y fijación interna según el principio de carga soportada es una terapéutica predecible y segura para el tratamiento de las fracturas en mandíbulas atróficas. La mayoría de las publicaciones recientes comparten resultados similares y lo consideran el procedimiento terapéutico de elección.
Palabras clave: Mandíbula atrófica, fractura, fijación interna, carga soportada.
Abstract
Aim: To present the therapeutic outcomes when performing open reduction and internal fixation according to the load bearing principle for the treatment of atrophic mandible fractures.
Case reports: The results of the treatment of 21 patients with 30 atrophic mandible fractures are presented. They were part of a total of 410 patients with mandible fractures, treated during the 1991- 2014 period, at a high complexity level hospital and private practice.
Conclusion: Open reduction and internal fixation performed according to the load bearing principle seems to be a safe and predictable treatment modality in atrophic mandible fractures. Most of recent publications report similar results and consider it the first choice treatment.
Key words: Atrophic mandible, fracture, internal fixation, load bearing principle.
Mandíbula atrófica fractura fijación interna carga soportada Atrophic mandible fracture internal fixation load bearing principle
Citar este artículo:
González A, Berrhau S, Jaciansky M, Carella S, Ries Centeno C. Tratamiento de las fracturas en mandíbulas atróficas: nuestra experiencia con la reducción abierta y fijación interna según el principio de carga soportada. Rev Asoc Odontol Argent. 2015 Dic 20;103(4):179-186. Disponible en: https://raoa.aoa.org.ar/revistas?roi=1034000184
Copiar Cita
Texto completo | PDF | Subir
Twitter | Whatsapp | Facebook | E-mail
Las obras publicadas en este sitio están bajo una Licencia Creative Commons Atribución-NoComercial 2.5 Argentina.
Revista indexada en:











Los artículos científicos de RAOA se identifican con DOI (Digital Object Identifier) Crossref.

Descargas / lecturas online: 1246

Accesos RAOA Id: 95
Auspiciantes del Website:







Revista de la Asociación Odontológica Argentina
La Revista de la Asociación Odontológica Argentina, RAOA, es la principal vía de expresión de la producción científica argentina en odontología y un vínculo de unión y medio de información para los colegas e instituciones del país y del exterior.
Versión electrónica ISSN: 2683-7226.
Título abreviado: Rev Asoc Odontol Argent