Utilización de limas manuales luego de la preparación de conductos simulados con los sistemas ProFile y ProTaper

The use of hand files after rotary preparation with ProFile and ProTaper in artificial root canals

ENDODONCIA  |  INVESTIGACIÓN CIENTÍFICA  |    OPEN ACCESS  |    PEER-REVIEWED

Utilización de limas manuales luego de la preparación de conductos simulados con los sistemas ProFile y ProTaper

The use of hand files after rotary preparation with ProFile and ProTaper in artificial root canals

Autor/es: Ronald Ordinola Zapata, Marco A.H. Duarte, Christian Nole Álvarez, Carlos Mendiola Aquino, Carlos Ortiz Franco, Francisco Balandrano Pinal, Clovis M. Bramante, Rodolfo Elías Hilú

Vol: 98  |  Nº 4  |  Sep 2010  |  Páginas: 331-335

Presentado: 10/04/2010  |  Aceptado: 10/07/2010  |  Publicado: 20/09/2010

Stable URL: https://raoa.aoa.org.ar/revistas/?roi=984000345   copiar


Texto completo    |    PDF    |    Citar este artículo


  X Twitter  |  WhatsApp  |  Facebook  |  E-mail


Resumen

Objetivo: Este estudio realizado in vitro evaluó el patrón de desgaste producido por las limas manuales tipo K Nitiflex #35 y #40 utilizadas como complemento en la porción apical de los conductos curvos simulados en bloques de resina acrílica preparados con los sistemas ProTaper y ProFile.

Materiales y métodos: Se evaluó el área en mm2 de material removido durante la preparación quirúrgica de 30 conductos artificiales fabricados en resina poliéster y estandarizados en base a longitud, radio y ángulo de la curvatura. Se designaron 3 etapas de evaluación que correspondían a los diámetros apicales de preparación propuestos por los fabricantes y al de las limas manuales Nitiflex #35 y #40. Imágenes pre y postoperatorias de cada etapa fueron digitalizadas utilizando un Scanner y el software Adobe Photoshop 7.0. Las imágenes fueron analizadas en el programa Image Tool (UTHSCSA) para determinar el área en mm2 de material removido durante la preparación en 3 niveles específicos: ensanchamiento total del conducto, zona apical interna y zona apical externa.

Resultados: Se encontró que los instrumentos de NiTi rotatorios fueron el factor más significativo para determinar la cantidad de área desgastada en todos los niveles evaluados. Aumentar el diámetro apical hasta la etapa correspondiente a la lima manual de #35 en los sistemas ProTaper y ProFile no aumentó significativamente el área de desgaste en la totalidad del conducto. Los sistemas de preparación rotatoria evaluados produjeron un menor desgaste a nivel de la zona apical externa en comparación con la técnica totalmente manual.

Conclusiones: La utilización complementaria de la lima de níquel titanio tipo K manual #35 mostró aumentar el diámetro apical sin alterar significativamente el patrón de desgaste original del conducto simulado instrumentado con los sistemas rotatorios ProFile y ProTaper. Mientras que el uso de una lima tipo K manual #40 produjo un aumento significativo en él.

Palabras clave: preparación biomecánica, diámetro apical, instrumentación rotatoria.



Abstract

Objective: This in vitro study evaluated the wear pattern produced by K-type hand files Nitiflex #35 and #40 used as complement in the apical portion of the simulated curved canals in acrylic resin blocks prepared with ProTaper and ProFile systems.

Materials and methods: The area in mm 2 of material removed during the surgical preparation of 30 artificial canals made in polyester resin and standardized according to the length and angle of curvature was assessed. Three designated evaluation stages that corresponded to the apical preparation diameters suggested by manufacturers and to #35 and #40 Nitiflex files were established. Pre and post-operative images of each stage were digitalized using a scanner and the Adobe Photoshop software. The images were analyzed using the Image Tool software (UTHSCSA) to determine the area in mm2 of material removed during preparation in 3 specific levels: total widening of the canal, external apical area and internal apical area.

Results: Rotary NiTi instruments were the most significant factor in determining the amount of removed material at all the tested levels. Increasing the apical diameter to the stage corresponding to the manual file #35 mm in both ProTaper and ProFile systems did not increase significantly the area of the artificial canal. The rotary preparation systems preserved more material at the external apical area in comparison to the manual technique.

Conclusions: The complementary use of a manual K-type file #35 showed an increase in the apical diameter without significantly altering the wear pattern of the original simulated canal whereas the use of K-type manual file #40 increased significantly the wear pattern of the original simulated canal.

Key words: biomechanical preparation, apical diameter, rotary instrumentation.


preparación biomecánica   diámetro apical   instrumentación rotatoria   biomechanical preparation   apical diameter   rotary instrumentation  

Citar este artículo:

Ordinola Zapata R, Duarte M, Nole Álvarez C, Mendiola Aquino C, Ortiz Franco C, Balandrano Pinal F, et al. Utilización de limas manuales luego de la preparación de conductos simulados con los sistemas ProFile y ProTaper. Rev Asoc Odontol Argent. 2010 Sep 20;98(4):331-335. Disponible en: https://raoa.aoa.org.ar/revistas?roi=984000345
 Copiar Cita


Texto completo    |    PDF   |    Subir  |  Home


  X Twitter  |  WhatsApp  |  Facebook  |  E-mail


Licencia Creative Commons

Las obras publicadas en este sitio están bajo una Licencia Creative Commons Atribución-NoComercial 4.0 Internacional

Revista indexada en:

lilacs Revista de la Asociación Odontológica Argentina scielo Revista de la Asociación Odontológica Argentina ebscohost Revista de la Asociación Odontológica Argentina
nucleo básico Revista de la Asociación Odontológica ArgentinaDirectory of Open Access Journals Revista de la Asociación Odontológica Argentina  google scholar Revista de la Asociación Odontológica Argentina
Dialnet Revista de la Asociación Odontológica ArgentinaMalena Revista de la Asociación Odontológica Argentina   ROAD Revista de la Asociación Odontológica Argentina
latindex Revista de la Asociación Odontológica ArgentinaBiblioteca Virtual de la Salud Revista de la Asociación Odontológica Argentina

Open Access RAOA  Creative Commons RAOA

Crossref

Los artículos científicos de RAOA se identifican con DOI (Digital Object Identifier) Crossref.



artículos leído en línea RAOA

Visitas al artículo: 1.771

artículos leído en línea RAOA

Lecturas en línea: 1.663

artículos leído en línea RAOA

Descargas del artículo: 108

artículos leído en línea RAOA

Accesos RAOA Id: 59

artículos leído en línea RAOA

Database ID: 2023001001

preparación biomecánica diámetro apical instrumentación rotatoria biomechanical preparation apical diameter rotary instrumentation

Auspiciantes del Website:

anuncio 3 Revista de la Asociación Odontológica Argentina
anuncio 3 Revista de la Asociación Odontológica Argentina


Google académico RAOA  Schema Org RAOA

Internet Archive RAOA  Dublin Core RAOA



Revista de la Asociación Odontológica Argentina

La Revista de la Asociación Odontológica Argentina, RAOA, es la principal vía de expresión de la producción científica argentina en odontología y un vínculo de unión y medio de información para los colegas e instituciones del país y del exterior. 
Versión impresa ISSN 0004-4881
Versión electrónica ISSN 2683-7226. 
DOI: 10.52979/raoa.1898
Título abreviado: Rev Asoc Odontol Argent




Flag Counter