Análisis tridimensional de la deformación ósea cortical en prótesis parcial fija implantosoportada con voladizo distal sobre implantes cortos en maxilar

Three-dimensional analysis of the cortical bone deformation in fixed partial prosthesis with distal cantilever on short implants in the maxilla

IMPLANTES  |  INVESTIGACIÓN CIENTÍFICA  |    OPEN ACCESS  |    PEER-REVIEWED

Análisis tridimensional de la deformación ósea cortical en prótesis parcial fija implantosoportada con voladizo distal sobre implantes cortos en maxilar

Three-dimensional analysis of the cortical bone deformation in fixed partial prosthesis with distal cantilever on short implants in the maxilla

Autor/es: Viviana Yolanda Flores, Enrique Fernández Bodereau

Vol: 105  |  Nº 3  |  Sep 2017  |  Páginas: 88-101

Presentado: 19/07/2017  |  Aceptado: 15/08/2017  |  Publicado: 30/09/2017

Stable URL: https://raoa.aoa.org.ar/revistas/?roi=1053000097   copiar


Texto completo    |    PDF    |    Citar este artículo


  X Twitter  |  WhatsApp  |  Facebook  |  E-mail


Resumen

Objetivo: Analizar la distribución de tensiones que provoca una fuerza axial en el modelo tridimensional, con el método de elementos finitos, en la prótesis parcial fija implantosoportada con voladizo distal (PPFIVD) sobre implantes dentales cortos en el sector posterior del maxilar parcialmente desdentado.

Materiales y métodos: Se crearon modelos geométricos del maxilar. Se diseñaron dos grupos y cuatro subgrupos. En zona premolar, se ubicaron implantes cortos Standard Plus SLA® (Straumann) de diferentes longitudes. Grupo A: PPFIVD con dos implantes, GA1 de 8 mm y GA2 de 4 mm. Grupo B: PPFIVD con un implante, GB1 de 8 mm y GB2 de 4 mm. Se aplicó una fuerza axial de 100 N a 30°.

Resultados: La distribución de las tensiones en los implantes fue menor en GA1 que en GA2, y en GB1 que en GB2. A nivel óseo, la distribución de las tensiones fue mayor en GA1 que en GA2, y en GB2 que en GB1. Se observaron microdeformaciones óseas periimplante y, posteriormente, desplazamiento del conjunto prótesis/implante.

Conclusiones: La PPFIVD sobre dos implantes de 8 y 4 mm ferulizados podría ser una alternativa viable al levantamiento del piso de seno maxilar. La PPFIVD sobre un implante de 4 mm no sería recomendable. Las tensiones elevadas provocaron menor rendimiento en geometría oseoimplantaria, evidenciando microdeformaciones en el tejido óseo tridimensional y desplazamientos de la PPFIVD.

Palabras clave: Análisis de elementos finitos, implante corto, prótesis parcial fija implantosoportada, voladizo distal.



Abstract

Aim: To analyze the stress distribution generated by axial forces in a three-dimensional model using the finite element method. The study was performed on implant-supported fixed partial prostheses with distal cantilever (PPFIVD) on short dental implants placed into the posterior partially edentulous maxilla.

Materials and methods: Geometric models of the maxilla were created. Two groups and subgroups were designed. Standard Plus SLA® (Straumann) short  implants of different lengths were located in the premolar area; Group A: PPFIVD with two implants, GA1 8 mm and GA2 4 mm, Group B: PPFIVD with an implant, GB1 8 mm and GB2 4 mm. An axial force of 100 N at 30° was applied.

Results: The distribution of tensions at the level of implants was lower in GA1 in relation to GA2, and GB1 was lower than GB2. At bone level the stress distribution was higher in GA1 than in GA2 and in GB1 was lower than in GB2. Bone periimplant microstrain as well as PPFIVD displacement were observed.

Conclusions: PPFIVD on two splinted 8 and 4 mm implants could be a viable alternative to the maxillary sinus floor lift. PPFIVD on a 4 mm implant would not be predictable. High tensions caused lower yields in bone-implant geometry, evidencing microdeformations in three-dimensional bone tissue and PPFIVD shifts.

Key words: Distal cantilever, finite element analysis, fixed partial prosthesis, short implants.


Análisis de elementos finitos   implante corto   prótesis parcial fija implantosoportada   voladizo distal   Distal cantilever   finite element analysis   fixed partial prosthesis   short implants  

Citar este artículo:

Flores V, Fernández Bodereau E. Análisis tridimensional de la deformación ósea cortical en prótesis parcial fija implantosoportada con voladizo distal sobre implantes cortos en maxilar. Rev Asoc Odontol Argent. 2017 Sep 30;105(3):88-101. Disponible en: https://raoa.aoa.org.ar/revistas?roi=1053000097
 Copiar Cita


Texto completo    |    PDF   |    Subir  |  Home


  X Twitter  |  WhatsApp  |  Facebook  |  E-mail


Licencia Creative Commons

Las obras publicadas en este sitio están bajo una Licencia Creative Commons Atribución-NoComercial 4.0 Internacional

Revista indexada en:

lilacs Revista de la Asociación Odontológica Argentina scielo Revista de la Asociación Odontológica Argentina ebscohost Revista de la Asociación Odontológica Argentina
nucleo básico Revista de la Asociación Odontológica ArgentinaDirectory of Open Access Journals Revista de la Asociación Odontológica Argentina  google scholar Revista de la Asociación Odontológica Argentina
Dialnet Revista de la Asociación Odontológica ArgentinaMalena Revista de la Asociación Odontológica Argentina   ROAD Revista de la Asociación Odontológica Argentina
latindex Revista de la Asociación Odontológica ArgentinaBiblioteca Virtual de la Salud Revista de la Asociación Odontológica Argentina

Open Access RAOA  Creative Commons RAOA

Crossref

Los artículos científicos de RAOA se identifican con DOI (Digital Object Identifier) Crossref.



artículos leído en línea RAOA

Visitas al artículo: 2.171

artículos leído en línea RAOA

Lecturas en línea: 2.063

artículos leído en línea RAOA

Descargas del artículo: 108

artículos leído en línea RAOA

Accesos RAOA Id: 36

artículos leído en línea RAOA

Database ID: 2023001001

Análisis de elementos finitos implante corto prótesis parcial fija implantosoportada voladizo distal Distal cantilever finite element analysis fixed partial prosthesis short implants

Auspiciantes del Website:

anuncio 3 Revista de la Asociación Odontológica Argentina
anuncio 3 Revista de la Asociación Odontológica Argentina


Google académico RAOA  Schema Org RAOA

Internet Archive RAOA  Dublin Core RAOA



Revista de la Asociación Odontológica Argentina

La Revista de la Asociación Odontológica Argentina, RAOA, es la principal vía de expresión de la producción científica argentina en odontología y un vínculo de unión y medio de información para los colegas e instituciones del país y del exterior. 
Versión impresa ISSN 0004-4881
Versión electrónica ISSN 2683-7226. 
DOI: 10.52979/raoa.1898
Título abreviado: Rev Asoc Odontol Argent




Flag Counter