Análisis histométrico de la capacidad de dos sistemas mecanizados para la instrumentación y conformación de conductos curvos simulados

Histometric comparison of simulated curved root canals prepared by two engine driven instrumentation systems

ENDODONCIA  |  INVESTIGACIÓN CIENTÍFICA  |    OPEN ACCESS  |    PEER-REVIEWED

Análisis histométrico de la capacidad de dos sistemas mecanizados para la instrumentación y conformación de conductos curvos simulados

Histometric comparison of simulated curved root canals prepared by two engine driven instrumentation systems

Autor/es: Osvaldo Zmener, Cornelis H. Pameijer, Susana Álvarez Serrano

Vol: 99  |  Nº 4  |  Sep 2011  |  Páginas: 325-333

Presentado: 20/03/2011  |  Aceptado: 20/04/2011  |  Publicado: 15/09/2011

Stable URL: https://raoa.aoa.org.ar/revistas/?roi=994000298   copiar


Texto completo    |    PDF    |    Citar este artículo


  X Twitter  |  WhatsApp  |  Facebook  |  E-mail


Resumen

El objetivo de este trabajo realizado en dos etapas fue comparar la capacidad de preparación de dos diferentes sistemas de instrumentación mecanizada, ProTaper (PTRS) y el sistema híbrido Ti- LOS (TiAET) utilizando para ello veinte (n = 20) conductos curvos simulados estandarizados (CSE) contenidos en bloques de resina acrílica transparente. La longitud de trabajo (LT) fue establecida a nivel de la terminación apical. En la primera etapa del estudio, los CSE fueron fotografiados en forma estandarizada mediante una cámara digital antes y después de la instrumentación con PTRS (n = 10) o TiAET (n = 10). El análisis de la configuración de los CSE fue realizado mediante una computadora y un programa analizador de imágenes midiendo en mm2 el espacio del conducto antes y después de la instrumentación desde la LT hasta su extremo coronario. En la segunda etapa, se realizaron secciones transversales a 1, 5 y 10 mm de la LT sobre los que se evaluaron y midieron en mm2 los cambios producidos en el área seccional instrumentada y en su perímetro circunferencial (expresado como porcentaje de circularidad). Las imagines fueron capturadas en un fotomicroscopio conectado a la computadora y evaluadas mediante el analizador de imágenes. Los datos obtenidos en las mediciones fueron sometidos a un análisis estadístico estableciéndose un nivel de significación de p < 0.05. En la primera etapa del estudio no hubo diferencias significativas en cuanto al espacio preparado con PTRS o TiAET (p > 0.05). Los resultados de la segunda etapa no revelaron diferencias significativas entre ambos sistemas de instrumentación a 1 y 5 mm de la LT (p > 0.05) mientras que TiLOS se comportó significativamente mejor a 10 mm de la LT. A este nivel PTRS removió de las paredes de los CSE una cantidad significativamente mayor de resina acrílica (p < 0.01) con una tendencia a remover más material hacia la pared interna de la curva.

Palabras clave: conductos radiculares curvos, conductos simulados, instrumentación, instrumentos mecanizados.



Abstract

The aim of this two-part study was to compare the shaping ability of two different engine-driven instrumentation systems, ProTaper (PTRS) and the recently introduced hybrid system TiLOS (TiAET) in twenty (n=20) simulated curved canals (CSE) in clear acrylic resin blocks. The working length (WL) was established at the apical terminus of the CSE. In part 1, canals were photographed preoperatively and after preparation with PTRS (n=10) or TiAET (n=10) using a digital camera. Assessment of the shape of the instrumented canals was completed with an image analysis software measuring the canal space (in mm2) from their apical end to the coronal zone. In part 2, the parameters evaluated were changes in cross-sectional canal area (in mm2) and the perimeter of the canals (expressed as the percentage of canal roundness) after instrumentation. Cross-sectional slides were obtained at 1, 5 and 10 mm from the WL. Then, the post operative images were captured with a photomicroscope coupled with the computer and analyzed with the image analysis software. Data were subjected to statistical analysis. In part 1, no significant differences were observed for the canal space after preparation with PTRS or TiAET (p>0.05). In part 2 no significant differences were observed between both instrumentation systems at 1 and 5 mm from the WL (p>0.05) while the TiAET system performed significantly better at the 10 mm level. At this level, PTRS removed significantly more acrylic resin than the TiAET system (p<0.01) with a tendency to remove more material towards the inner side of the CSE walls.

Key words: curved root canals, engine-driven instruments, root canal preparation, simulated root canals.
 


conductos radiculares curvos   conductos simulados   instrumentación   instrumentos mecanizados   curved root canals   engine-driven instruments   root canal preparation   simulated root canals  

Citar este artículo:

Zmener O, Pameijer C, Álvarez Serrano S. Análisis histométrico de la capacidad de dos sistemas mecanizados para la instrumentación y conformación de conductos curvos simulados. Rev Asoc Odontol Argent. 2011 Sep 15;99(4):325-333. Disponible en: https://raoa.aoa.org.ar/revistas?roi=994000298
 Copiar Cita


Texto completo    |    PDF   |    Subir  |  Home


  X Twitter  |  WhatsApp  |  Facebook  |  E-mail


Licencia Creative Commons

Las obras publicadas en este sitio están bajo una Licencia Creative Commons Atribución-NoComercial 4.0 Internacional

Revista indexada en:

lilacs Revista de la Asociación Odontológica Argentina scielo Revista de la Asociación Odontológica Argentina ebscohost Revista de la Asociación Odontológica Argentina
nucleo básico Revista de la Asociación Odontológica ArgentinaDirectory of Open Access Journals Revista de la Asociación Odontológica Argentina  google scholar Revista de la Asociación Odontológica Argentina
Dialnet Revista de la Asociación Odontológica ArgentinaMalena Revista de la Asociación Odontológica Argentina   ROAD Revista de la Asociación Odontológica Argentina
latindex Revista de la Asociación Odontológica ArgentinaBiblioteca Virtual de la Salud Revista de la Asociación Odontológica Argentina

Open Access RAOA  Creative Commons RAOA

Crossref

Los artículos científicos de RAOA se identifican con DOI (Digital Object Identifier) Crossref.



artículos leído en línea RAOA

Visitas al artículo: 1.957

artículos leído en línea RAOA

Lecturas en línea: 1.861

artículos leído en línea RAOA

Descargas del artículo: 96

artículos leído en línea RAOA

Accesos RAOA Id: 185

artículos leído en línea RAOA

Database ID: 2023001001

conductos radiculares curvos conductos simulados instrumentación instrumentos mecanizados curved root canals engine-driven instruments root canal preparation simulated root canals

Auspiciantes del Website:

anuncio 3 Revista de la Asociación Odontológica Argentina
anuncio 3 Revista de la Asociación Odontológica Argentina


Google académico RAOA  Schema Org RAOA

Internet Archive RAOA  Dublin Core RAOA



Revista de la Asociación Odontológica Argentina

La Revista de la Asociación Odontológica Argentina, RAOA, es la principal vía de expresión de la producción científica argentina en odontología y un vínculo de unión y medio de información para los colegas e instituciones del país y del exterior. 
Versión impresa ISSN 0004-4881
Versión electrónica ISSN 2683-7226. 
DOI: 10.52979/raoa.1898
Título abreviado: Rev Asoc Odontol Argent




Flag Counter