Biocompatibilidad de un ionómero vítreo modificado con resina implantado en el tejido celular subcutáneo de la rata

Biocompatibility of a resin-modified glass ionomer implanted in the subcutaneous connective tissue of the rat

ENDODONCIA  |  INVESTIGACIÓN CIENTÍFICA  |    OPEN ACCESS  |    PEER-REVIEWED

Biocompatibilidad de un ionómero vítreo modificado con resina implantado en el tejido celular subcutáneo de la rata

Biocompatibility of a resin-modified glass ionomer implanted in the subcutaneous connective tissue of the rat

Autor/es: Osvaldo Zmener, Gabriel Kokubu, Daniel Grana

Vol: 101  |  Nº 3  |  Sep 2013  |  Páginas: 102-109

Presentado: 26/03/2012  |  Aceptado: 13/08/2012  |  Publicado: 20/09/2013

Stable URL: https://raoa.aoa.org.ar/revistas/?roi=1013000235   copiar


Texto completo    |    PDF    |    Citar este artículo


  X Twitter  |  WhatsApp  |  Facebook  |  E-mail


Resumen

Objetivo: Analizar la respuesta del tejido celular subcutáneo de la rata ante la implantación de un ionómero vítreo modificado con resinas.

Materiales y métodos: En el tejido celular subcutáneo de 15 ratas, se implantaron tubos de silicona obturados a ras, en ambos extremos, con Fuji PLUS (FPL) –un cemento de ionómero vítreo modificado con resinas– o EndoFill (EFL) –un sellador endodóntico a base de óxido de cinc y eugenol–, considerando este último como control positivo. Las paredes laterales de los tubos (PLT) fueron utilizadas como control negativo. Luego de 10, 30 y 90 días posimplantación, los animales fueron sacrificados; y los implantes, juntamente con los tejidos circundantes, fueron removidos, fijados en solución de formol al 10% y, finalmente, procesados para su estudio histológico.

Resultados: El análisis histológico demostró que, en todos los casos y en todos los períodos experimentales, el contacto directo con FPL y EFL produjo una reacción inflamatoria severa compuesta por polimorfonucleares neutrófilos, linfocitos, plasmocitos, macrófagos, fibroblastos y vasos de neoformación. Se observaron numerosas partículas de FPL y EFL dispersas en los tejidos, muchas de ellas fagocitadas por macrófagos y células gigantes multinucleadas, o dentro de la luz de los vasos sanguíneos, lo cual sugiere la transportación de dichas partículas hacia zonas alejadas. A los 10 días posimplantación, la reacción de los tejidos en contacto con PLT fue considerada mínima, pero éstos retornaron a la normalidad luego de 30 y 90 días. En todos los períodos estudiados, no se hallaron diferencias significativas (P>0,05) entre FPL o EFL, pero sí las hubo entre estos materiales y los PLT (P<0,05).

Conclusión: Los resultados demostraron que, luego de 90 días, tanto FPL como EFL provocaron reacciones severas en el tejido celular subcutáneo de la rata. Si bien los materiales analizados no fueron originariamente desarrollados para ser utilizados en contacto directo con la pulpa, la reacción inflamatoria y la intensa actividad macrofágica provocada por la progresiva degradación de éstos sugiere que, en caso de producirse una exposición accidental o inadvertida, es preciso evitar el contacto directo con la pulpa protegiéndola mediante materiales biocompatibles adecuados.

Palabras clave: Biocompatibilidad, ionómeros vítreos, óxido de cinc y eugenol, respuesta tisular.



Abstract

Aim: To analyze the reaction of the subcutaneous connective tissue of the rat to a resin-modified glass ionomer cement and a zinc oxide and eugenol-based endodontic sealer used as the control.

Materials and methods: Silicone tubes filled flush at both ends with a resin-modified glass ionomer cement Fuji Plus (FPL) or with the zinc oxide and eugenol-based endodontic sealer EndoFill (EFL)as the positive control, were implanted in the subcutaneous connective tissue of 15 rats. The lateral silicone walls of the tubes (PLT) were used as negative control. After 10, 30 and 90 days the animals were sacrificed, the implants were removed along with the surrounding tissues, fixed in 10% buffered formalin solution and then processed for histological analysis.

Results: The tissues in direct contact with both FPL and EFL showed severe reactions which persisted after 90 days. There was a great concentration of inflammatory cells mainly composed by polymorphonuclear neutrophyls, lymphocytes, plasmocytes, macrophages, fibroblasts and newly formed vessels. Many particles which appeared to have been released from the tested materials were observed to be randomly distributed within the tissues surrounding the ends of the implants or phagocytized by macrophages and multinucleated giant cells. These particles were also found within the lumen of newly formed vessels, suggesting particle transportation. Although the tissues in contact with PLT showed a mild reaction at the short-term observation period, they return to the normal after 30 and 90 days. Statistical analysis of the data revealed that in all experimental periods there were no statistical differences (P>0.05) between FPL and EFL. However, significant differences were found between both FPL and EFL and PLT (P<0.05).

Conclusion: The results showed that the subcutaneous connective tissue of the rat revealed a severe inflammatory reaction to FPL and EFL after 90 days. Although that FPL and EFL were not originally intended to be in direct contact with pulpal tissues, accidental pulp exposure can always occur in clinical dentistry and therefore, when using these materials adverse tissue reactions has to be prevented by using adequate pulp capping materials.

Key words: Biocompatibility, glass ionomers, zinc oxide and eugenol, tissue response.


Biocompatibilidad   ionómeros vítreos   óxido de cinc y eugenol   respuesta tisular   Biocompatibility   glass ionomers   zinc oxide and eugenol   tissue response  

Citar este artículo:

Zmener O, Kokubu G, Grana D. Biocompatibilidad de un ionómero vítreo modificado con resina implantado en el tejido celular subcutáneo de la rata. Rev Asoc Odontol Argent. 2013 Sep 20;101(3):102-109. Disponible en: https://raoa.aoa.org.ar/revistas?roi=1013000235
 Copiar Cita


Texto completo    |    PDF   |    Subir  |  Home


  X Twitter  |  WhatsApp  |  Facebook  |  E-mail


Licencia Creative Commons

Las obras publicadas en este sitio están bajo una Licencia Creative Commons Atribución-NoComercial 4.0 Internacional

Revista indexada en:

lilacs Revista de la Asociación Odontológica Argentina scielo Revista de la Asociación Odontológica Argentina ebscohost Revista de la Asociación Odontológica Argentina
nucleo básico Revista de la Asociación Odontológica ArgentinaDirectory of Open Access Journals Revista de la Asociación Odontológica Argentina  google scholar Revista de la Asociación Odontológica Argentina
Dialnet Revista de la Asociación Odontológica ArgentinaMalena Revista de la Asociación Odontológica Argentina   ROAD Revista de la Asociación Odontológica Argentina
latindex Revista de la Asociación Odontológica ArgentinaBiblioteca Virtual de la Salud Revista de la Asociación Odontológica Argentina

Open Access RAOA  Creative Commons RAOA

Crossref

Los artículos científicos de RAOA se identifican con DOI (Digital Object Identifier) Crossref.



artículos leído en línea RAOA

Visitas al artículo: 2.252

artículos leído en línea RAOA

Lecturas en línea: 2.142

artículos leído en línea RAOA

Descargas del artículo: 110

artículos leído en línea RAOA

Accesos RAOA Id: 207

artículos leído en línea RAOA

Database ID: 2023001001

Biocompatibilidad ionómeros vítreos óxido de cinc y eugenol respuesta tisular Biocompatibility glass ionomers zinc oxide and eugenol tissue response

Auspiciantes del Website:

anuncio 3 Revista de la Asociación Odontológica Argentina
anuncio 3 Revista de la Asociación Odontológica Argentina


Google académico RAOA  Schema Org RAOA

Internet Archive RAOA  Dublin Core RAOA



Revista de la Asociación Odontológica Argentina

La Revista de la Asociación Odontológica Argentina, RAOA, es la principal vía de expresión de la producción científica argentina en odontología y un vínculo de unión y medio de información para los colegas e instituciones del país y del exterior. 
Versión impresa ISSN 0004-4881
Versión electrónica ISSN 2683-7226. 
DOI: 10.52979/raoa.1898
Título abreviado: Rev Asoc Odontol Argent




Flag Counter