Comparación entre diferentes rellenos óseos y membranas reabsorbibles mediante microtomografía de alta resolución. Estudio preliminar en conejos

Comparison between different bone fillers and reabsorbable membranes using high resolution micro-tomography. Preliminary study in rabbits

IMPLANTES  |  INVESTIGACIÓN CIENTÍFICA  |    OPEN ACCESS  |    PEER-REVIEWED

Comparación entre diferentes rellenos óseos y membranas reabsorbibles mediante microtomografía de alta resolución. Estudio preliminar en conejos

Comparison between different bone fillers and reabsorbable membranes using high resolution micro-tomography. Preliminary study in rabbits

Autor/es: Guillermo E. Dedossi, Martín G. Benassi, Leonardo Uribe Echeverría, Ismael Rodríguez, Enrique Fernández Bodereau

Vol: 105  |  Nº 2  |  Jun 2017  |  Páginas: 42-53

Presentado: 23/03/2017  |  Aceptado: 10/07/2017  |  Publicado: 20/06/2017

Stable URL: https://raoa.aoa.org.ar/revistas/?roi=1052000105   copiar


Texto completo    |    PDF    |    Citar este artículo


  X Twitter  |  WhatsApp  |  Facebook  |  E-mail


Resumen

Objetivo: Evaluar el comportamiento de diferentes membranas y materiales para relleno óseo en defectos críticos, en calotas de conejos, mediante microtomografía.

Materiales y métodos: En 12 conejos machos de 3 kg se realizaron 4 defectos en la calota craneana, de espesor óseo total. Se los dividió aleatoriamente en tres subgrupos según el tipo de membrana de barrera utilizada. Los defectos se rellenaron con hueso bovino desproteinizado particulado Bio-Oss® (Geistlich-Pharma AG, Wolhusen, Suiza), con hidroxiapatita humana particulada MinerOss® (BioHorizons, Birmingham, AL, Estados Unidos), y con material dentario particulado (Banco de tejidos de Inbiomed S.A., Córdoba, Argentina); el cuarto defecto no se rellenó. Algunos de los especímenes fueron sacrificados a las 4 semanas, y otros, a las 8 semanas. Los niveles de mineralización se evaluaron con microtomografía de alta resolución.

Resultados: Los mayores porcentajes de mineralización (media) se registraron al considerar las membranas amniocoriónicas (83,63%), seguidas de las de colágeno (81,44%) y, finalmente, de las membranas fascia lata (80,63%), pero las diferencias no resultaron estadísticamente significativas (p>0,05), por lo que se agrupó a todas estas membranas en un único subconjunto homogéneo (tabla 7). Los sitios injertados con diente descelularizado (96,83%) y Bio-Oss (88,42%) arrojaron los porcentajes de mineralización más elevados, pero sin diferenciarse significativamente entre sí (subconjunto 2); en tanto que MinerOss registró porcentajes de mineralización bajos (76% de media), con valores levemente superiores a los del grupo de cavidades sin relleno agregado (70,33%), por lo que la diferencia entre estos no resultó significativa (subconjunto 1). Cabe aclarar que los materiales del subconjunto 1 se diferenciaron significativamente de los del grupo 2 (tabla 4).

Conclusiones: Las tres membranas utilizadas no mostraron diferencias estadísticas entre sí en ninguno de los dos períodos de tiempo. Sí hubo diferencias estadísticas entre los materiales de relleno utilizados; los defectos tratados con diente particulado y con hueso bovino desproteinizado evidenciaron gran cantidad de material calcificado, mientras que los defectos tratados con hidroxiapatita humana y los que no fueron rellenados mostraron menor cantidad.

Palabras clave: Amniótica, colágeno, diente particulado, fascia lata, hidroxiapatita, hueso, membranas, microtomografía, regeneración, sustitutos óseos.



Abstract

Aim: To evaluate the behavior of different membranes and materials for filling bone critical defects in rabbits by micro-tomography.

Materials and methods: Four defects were prepared in the cranial cap of 12 3 kg male rabbits of 3 kg, of including total bone thickness. They were randomly divided into three subgroups according to the type of barrier membrane to be used. The defects were filled with the deproteinized bovine bone particulate Bio-Oss® (Geistlich-Pharma AG, Wolhusen, Switzerland), with particulate human hydroxyapatite Miner- Oss® (BioHorizons, Birmingham, AL, USA), with particulate dental material (Tissue Bank Foundation, Inbiomed S.A., Córdoba, Argentina), and the last one was left without the addition of filler material. The animals were sacrificed at 4 and 8 weeks. Levels of mineralization were assessed by high resolution micro-tomography.

Results: The highest percentages of mineralization (average) were recorded considering the amnio-corionic membranes (83.63%) followed by collagen (81.44%) and finally the fascia lata membranes (80.63%), but the differences were not statistically significant (p>0.05) and all membranes could be grouped into a single homogeneous subset (table 7). The sites grafted with decellularized tooth (96.83%) and Bio-Oss (88.42%), recorded the highest percentages of mineralization, but did not differentiate significantly from each other (subset 2). MinerOss showed low percentages of mineralization (76%), with values slightly higher than those recorded in the group of cavities without added filler (70.33%), so that the difference between them was not significant (subset 1). It should be noted that the materials of subset 1 differed significantly from those of group 2 (table 4).

Conclusions: The three membranes used did not show statistical differences between them, in any of the two time periods used. There were statistical differences between the filling materials evidencing the presence of a large quantity of calcified material in the defects treated with particulate tooth and with deproteinized bovine bone and while smaller amounts of calcified material was registered in the case of defects treated with human hydroxyapatite and those that were not treated.

Key words: Amniotic, bone, bone substitutes, collagen, fascia lata, hydroxyapatite, membranes, micro-tomography, particulate tooth, regeneration.


Amniótica   colágeno   diente particulado   fascia lata   hidroxiapatita   hueso   membranas   microtomografía   regeneración   sustitutos óseos   Amniotic   bone   bone substitutes   collagen   fascia lata   hydroxyapatite   membranes   micro-tomography   particulate tooth   regeneration  

Citar este artículo:

Dedossi G, Benassi M, Uribe Echeverría L, Rodríguez I, Fernández Bodereau E. Comparación entre diferentes rellenos óseos y membranas reabsorbibles mediante microtomografía de alta resolución. Estudio preliminar en conejos. Rev Asoc Odontol Argent. 2017 Jun 20;105(2):42-53. Disponible en: https://raoa.aoa.org.ar/revistas?roi=1052000105
 Copiar Cita


Texto completo    |    PDF   |    Subir  |  Home


  X Twitter  |  WhatsApp  |  Facebook  |  E-mail


Licencia Creative Commons

Las obras publicadas en este sitio están bajo una Licencia Creative Commons Atribución-NoComercial 4.0 Internacional

Revista indexada en:

lilacs Revista de la Asociación Odontológica Argentina scielo Revista de la Asociación Odontológica Argentina ebscohost Revista de la Asociación Odontológica Argentina
nucleo básico Revista de la Asociación Odontológica ArgentinaDirectory of Open Access Journals Revista de la Asociación Odontológica Argentina  google scholar Revista de la Asociación Odontológica Argentina
Dialnet Revista de la Asociación Odontológica ArgentinaMalena Revista de la Asociación Odontológica Argentina   ROAD Revista de la Asociación Odontológica Argentina
latindex Revista de la Asociación Odontológica ArgentinaBiblioteca Virtual de la Salud Revista de la Asociación Odontológica Argentina

Open Access RAOA  Creative Commons RAOA

Crossref

Los artículos científicos de RAOA se identifican con DOI (Digital Object Identifier) Crossref.



artículos leído en línea RAOA

Visitas al artículo: 2.309

artículos leído en línea RAOA

Lecturas en línea: 2.221

artículos leído en línea RAOA

Descargas del artículo: 88

artículos leído en línea RAOA

Accesos RAOA Id: 243

artículos leído en línea RAOA

Database ID: 2023001001

Amniótica colágeno diente particulado fascia lata hidroxiapatita hueso membranas microtomografía regeneración sustitutos óseos Amniotic bone bone substitutes collagen fascia lata hydroxyapatite membranes micro-tomography particulate tooth regeneration

Auspiciantes del Website:

anuncio 3 Revista de la Asociación Odontológica Argentina
anuncio 3 Revista de la Asociación Odontológica Argentina


Google académico RAOA  Schema Org RAOA

Internet Archive RAOA  Dublin Core RAOA



Revista de la Asociación Odontológica Argentina

La Revista de la Asociación Odontológica Argentina, RAOA, es la principal vía de expresión de la producción científica argentina en odontología y un vínculo de unión y medio de información para los colegas e instituciones del país y del exterior. 
Versión impresa ISSN 0004-4881
Versión electrónica ISSN 2683-7226. 
DOI: 10.52979/raoa.1898
Título abreviado: Rev Asoc Odontol Argent




Flag Counter