">


Evaluación del ajuste apical y la adaptación de los conos de gutapercha ProTaper Next, ProTaper Gold, WaveOne Gold y Reciproc Blue en conductos simulados instrumentados con estos sistemas

Evaluation of the apical tugback and adaptation of ProTaper Next, ProTaper Gold, WaveOne Gold and Reciproc Blue gutta-percha cones in simulated canals prepared with these systems

ENDODONCIA  |  INVESTIGACIÓN CIENTÍFICA  |    OPEN ACCESS  |    PEER-REVIEWED

Evaluación del ajuste apical y la adaptación de los conos de gutapercha ProTaper Next, ProTaper Gold, WaveOne Gold y Reciproc Blue en conductos simulados instrumentados con estos sistemas

Evaluation of the apical tugback and adaptation of ProTaper Next, ProTaper Gold, WaveOne Gold and Reciproc Blue gutta-percha cones in simulated canals prepared with these systems

Autor/es: Pablo Pérez Rodríguez, Ciro Quiroga, Luis Alejandro Grillone, Alejandra Migueles, Laura Pinasco, Fernando Goldberg

Vol: 106  |  Nº 2  |  Jun 2018  |  Páginas: 44-50

Presentado: 03/04/2018  |  Aceptado: 22/06/2018  |  Publicado: 10/07/2018

Stable URL: https://raoa.aoa.org.ar/revistas/?roi=1062000042   copiar


Texto completo    |    PDF    |    Citar este artículo


  X Twitter  |  WhatsApp  |  Facebook  |  E-mail


Resumen

Objetivo: Evaluar el ajuste y la adaptación apical de los conos de gutapercha de cuatro diferentes sistemas de instrumentación y obturación endodóntica en conductos curvos simulados.

Materiales y métodos: Se emplearon 4 Endo Training Blocks (Dentsply Sirona) con conductos curvos simulados, instrumentados hasta el límite de trabajo, fijado en el orificio de salida del conducto. Con ese propósito se empleó un tope metálico confeccionado ad hoc, ajustado en la concavidad de la salida del conducto, a fin de asegurar el límite de la instrumentación en todos los bloques de trabajo. El tope metálico se mantuvo en la posición por medio de una morsa de mesa. Los conductos fueron permeabilizados con una lima tipo K #10 (Dentsply Sirona). A continuación, se procedió con los protocolos de instrumentación de los sistemas por evaluar en cada Endo Training Block. Se emplearon los sistemas ProTaper Next (Dentsply Sirona), ProTaper Gold (Dentsply Sirona), WaveOne Gold (Dentsply Sirona) y Reciproc Blue (VDW) de acuerdo con las especificaciones del fabricante (grupos 1, 2, 3 y 4 respectivamente). Los conductos fueron irrigados con agua destilada a cada cambio de instrumento y al finalizar la preparación, y secados con conos de papel. Luego se evaluaron, en el respectivo Endo Training Block, el ajuste y la adaptación apical a la longitud de trabajo de 10 conos de gutapercha del sistema correspondiente. Para la evaluación del ajuste, se introdujeron los conos de gutapercha en el conducto simulado respectivo y se elevaron ambos hasta 10 cm de altura, manteniéndolos durante 10 segundos. Cuando se conservaban en esa situación, se consideraba que el cono ajustaba; si se desprendían antes de ese lapso, se establecía la falta de ajuste. Así mismo, se constató en cada caso su adaptación apical a la longitud de trabajo con un microscopio clínico operativo a 8,5X. Para la evaluación total se consideraron las siguientes categorías: 1, el cono de gutapercha llegaba a la longitud de trabajo y ajustaba; 2, el cono de gutapercha llegaba a la longitud de trabajo, pero no ajustaba; 3, el cono de gutapercha no llegaba a la longitud de trabajo; y 4, el cono de gutapercha sobrepasaba la longitud de trabajo.

Resultados: Entre los grupos 1, 3 y 4 no se observaron variables intrasistemas de ajuste y adaptación apical a la longitud de trabajo. En el grupo 2 sí las hubo, pero la diferencia entre grupos no fue significativa (P>0,05).

Conclusiones: De los cuatro sistemas utilizados, en tres de ellos el empleo de un cono único de gutapercha garantizó, en todas las pruebas, la adaptación y el ajuste a la longitud de trabajo.

Palabras clave: Ajuste, conos de gutapercha, longitud de trabajo.



Abstract

Aim: To evaluate in the tugback and apical adaptation at the working length of four different mechanized systems gutta-percha cones in simulated curved canals.

Materials and methods: Four Endo Training Blocks (Dentsply Sirona) with simulated curved canals were instrumented up to the working length established at the orifice located in the canal exit. A metal stop was adjusted in the concavity present at the exit of the canal to ensure the working length during instrumentation in all blocks. The metal stop was maintained using a table walrus. Canal patency was achieved with a #10 K file (Dentsply Sirona). Then the instrumentation protocols for the different systems were performed in each Endo Training Block. ProTaper Next (Dentsply Sirona), ProTaper Gold (Dentsply Sirona), WaveOne Gold (Dentsply Sirona) and Reciproc Blue (VDW) were used according to the manufacturers’ instructions (groups 1, 2, 3 and 4 respectively). The canals were irrigated with distilled water between instruments and at the end of the preparation and dried with paper points. Then, the tugback and the apical adaptation at the working length of 10 gutta-percha cones of each system were evaluated in the corresponding Endo Training Block. For the tugback analysis, the gutta-percha cones were introduced in the respective simulated canal and both were raised up to 10 cm in height, holding them for 10 seconds. If the cones remained intact in their position, it was considered that the cone tugback was appropriate, if the cones were detached, a lack of tugback was considered. Likewise, a  linical operating microscope at 8.5X was used to confirm the apical adaptation to the working length in each case. For the overall evaluation the following categories were considered: 1, the gutta-percha cone reached the working length with tugback; 2, the gutta-percha cone reached the working length without tugback; 3, the gutta-percha cone did not reach the working length; 4, the gutta-percha cone exceeded the working length. 

Results: In three groups 1, 3 and 4 they were not found intra-systems variables in the tugback at the working length. In one group there were observed intra-systems variables but the differences between groups were not statistically significant (P>0.05).

Conclusion: In three of the groups the single gutta-percha cones guaranties, in all the probes, an adequate adaptation and tugback at the working length.

Key words: Gutta-percha cones, tugback, working length.


Ajuste   conos de gutapercha   longitud de trabajo   Gutta-percha cones   tugback   working length  

Citar este artículo:

Pérez Rodríguez P, Quiroga C, Grillone L, Migueles A, Pinasco L, Goldberg F. Evaluación del ajuste apical y la adaptación de los conos de gutapercha ProTaper Next, ProTaper Gold, WaveOne Gold y Reciproc Blue en conductos simulados instrumentados con estos sistemas. Rev Asoc Odontol Argent. 2018 Jun 10;106(2):44-50. Disponible en: https://raoa.aoa.org.ar/revistas?roi=1062000042
 Copiar Cita


Texto completo    |    PDF   |    Subir  |  Home


  X Twitter  |  WhatsApp  |  Facebook  |  E-mail


Licencia Creative Commons

Las obras publicadas en este sitio están bajo una Licencia Creative Commons Atribución-NoComercial 4.0 Internacional

Revista indexada en:

lilacs Revista de la Asociación Odontológica Argentina scielo Revista de la Asociación Odontológica Argentina ebscohost Revista de la Asociación Odontológica Argentina
nucleo básico Revista de la Asociación Odontológica ArgentinaDirectory of Open Access Journals Revista de la Asociación Odontológica Argentina  google scholar Revista de la Asociación Odontológica Argentina
Dialnet Revista de la Asociación Odontológica ArgentinaMalena Revista de la Asociación Odontológica Argentina   ROAD Revista de la Asociación Odontológica Argentina
latindex Revista de la Asociación Odontológica ArgentinaBiblioteca Virtual de la Salud Revista de la Asociación Odontológica Argentina

Open Access RAOA  Creative Commons RAOA

Crossref

Los artículos científicos de RAOA se identifican con DOI (Digital Object Identifier) Crossref.



artículos leído en línea RAOA

Visitas al artículo: 1.470

artículos leído en línea RAOA

Lecturas en línea: 1.433

artículos leído en línea RAOA

Descargas del artículo: 37

artículos leído en línea RAOA

Accesos RAOA Id: 58

artículos leído en línea RAOA

Database ID: 2023001001

Ajuste conos de gutapercha longitud de trabajo Gutta-percha cones tugback working length

Auspiciantes del Website:

anuncio 3 Revista de la Asociación Odontológica Argentina
anuncio 3 Revista de la Asociación Odontológica Argentina


Google académico RAOA  Schema Org RAOA

Internet Archive RAOA  Dublin Core RAOA



Revista de la Asociación Odontológica Argentina

La Revista de la Asociación Odontológica Argentina, RAOA, es la principal vía de expresión de la producción científica argentina en odontología y un vínculo de unión y medio de información para los colegas e instituciones del país y del exterior. 
Versión impresa ISSN 0004-4881
Versión electrónica ISSN 2683-7226. 
DOI: 10.52979/raoa.1898
Título abreviado: Rev Asoc Odontol Argent




Flag Counter