Biocompatibilidad de dos materiales bioactivos en el tejido óseo de la rata

Biocompatibility of two bioactive materials in the bone tissue of the rat

ENDODONCIA  |  INVESTIGACIÓN CIENTÍFICA  |    OPEN ACCESS  |    PEER-REVIEWED

Biocompatibilidad de dos materiales bioactivos en el tejido óseo de la rata

Biocompatibility of two bioactive materials in the bone tissue of the rat

Autor/es: Osvaldo Zmener, Gabriel Kokubu, Cornelis H. Pameijer

Vol: 105  |  Nº 3  |  Sep 2017  |  Páginas: 102-108

Presentado: 22/02/2017  |  Aceptado: 14/08/2017  |  Publicado: 30/09/2017

Stable URL: https://raoa.aoa.org.ar/revistas/?roi=1053000098   copiar


Texto completo    |    PDF    |    Citar este artículo


  X Twitter  |  WhatsApp  |  Facebook  |  E-mail


Resumen

Objetivos: Comparar la biocompatibilidad y la actividad osteogénica del material bioactivo experimental Activa PC y de MTA color blanco, por medio de un modelo de implantación en tibia de rata.

Materiales y métodos: En las tibias de 20 (n=20) ratas Wistar macho de aproximadamente 350 gramos, se implantaron tubos de silicona estériles obturados a ras con Activa PC (Pulpdent Corp., Watertown, Estados Unidos) o MTA (Angelus, Londrina, Brasil). Los animales se separaron en dos grupos de 10 (n=10). La eutanasia de uno de los grupos fue realizada a los 15 días, mientras que la del grupo restante se realizó a los 60 días posimplantación. Las tibias fueron removidas, se fijaron en formol-buffer al 10%, y se descalcificaron y procesaron para su estudio histológico. La evaluación fue realizada en base a tres categorías, y los resultados se analizaron por medio de la prueba de Wilcoxon y el test no paramétrico de Mann-Whitney, con un nivel de significación de P<0,05.

Resultados: A los 15 días se observó la aposición de nuevo tejido óseo sano. Este fenómeno se incrementó considerablemente al finalizar la experiencia (60 días). No hubo diferencias significativas (P>0,05) entre Activa PC y MTA Angelus en cada uno de los períodos de observación, pero sí las hubo (P<0,05) cuando se compararon los resultados obtenidos a 15 y 60 días.

Conclusiones: Activa PC y MTA Angelus se comportaron como materiales biocompatibles en tibias de rata, y su función bioactiva se incrementó significativamente en función del tiempo transcurrido, favoreciendo ambos materiales el proceso de reparación ósea.

Palabras clave: Biocompatibilidad, materiales bioactivos, MTA, osteogénesis.



Abstract

Aim: To analyze the biocompatibility and osteogenic activity of Activa PC, a new experimental biomaterial, when compared with Angelus white MTA, using the rat tibia as the implantation model.

Materials and methods: Sterilized silicone tubes were filled flush with Activa (Pulpdent Corp., Watertown, USA) or MTA (Angelus, Londrina, Brazil) and then implanted into the tibias of twenty (n=20) male Wistar rats of approximately 350 g weight. The animals were separated into two groups of 10 animals each. One group was euthanized after 15 days and the other after 60 days postoperatively. The tibias were removed, fixed in 10% buffered formalin, decalcified and submitted for routine histological preparation. Three scores were established for evaluation and they were statistically compared using the Wilcoxon test and the Mann-Whitney non parametric test. The significance level was established at P<0.05.

Results: After 15 days aposition of new healthy mineralized tissue in direct contact with Activa PC and MTA was observed. The amount of the new bone formation increased considerably at the end of the experiment (60 days). No significant differences (P>0.05) were observed between ACPc and WMTA within each observation period. However, significant differences (P<0.05) were found when the 15 and 60-day results were compared.

Conclusions: Activa PC behaved as a biocompatible material when implanted into the rat tibia. After 60 days its bioactive function was similar to MTA allowing for the bone reparative process.

Key words: Bioactive materials, biocompatibility, MTA, osteogenic activity.


Biocompatibilidad   materiales bioactivos   MTA   osteogénesis   Bioactive materials   biocompatibility   MTA   osteogenic activity  

Citar este artículo:

Zmener O, Kokubu G, Pameijer C. Biocompatibilidad de dos materiales bioactivos en el tejido óseo de la rata. Rev Asoc Odontol Argent. 2017 Sep 30;105(3):102-108. Disponible en: https://raoa.aoa.org.ar/revistas?roi=1053000098
 Copiar Cita


Texto completo    |    PDF   |    Subir  |  Home


  X Twitter  |  WhatsApp  |  Facebook  |  E-mail


Licencia Creative Commons

Las obras publicadas en este sitio están bajo una Licencia Creative Commons Atribución-NoComercial 4.0 Internacional

Revista indexada en:

lilacs Revista de la Asociación Odontológica Argentina scielo Revista de la Asociación Odontológica Argentina Scopus Revista de la Asociación Odontológica Argentina
nucleo básico Revista de la Asociación Odontológica ArgentinaDirectory of Open Access Journals Revista de la Asociación Odontológica Argentina  google scholar Revista de la Asociación Odontológica Argentina
Dialnet Revista de la Asociación Odontológica ArgentinaMalena Revista de la Asociación Odontológica Argentina   ROAD Revista de la Asociación Odontológica Argentina
latindex Revista de la Asociación Odontológica ArgentinaBiblioteca Virtual de la Salud Revista de la Asociación Odontológica Argentinaebscohost Revista de la Asociación Odontológica Argentina

Open Access RAOA  Creative Commons RAOA

Crossref

Los artículos científicos de RAOA se identifican con DOI (Digital Object Identifier) Crossref.



artículos leído en línea RAOA

Visitas al artículo: 2.858

artículos leído en línea RAOA

Lecturas en línea: 2.676

artículos leído en línea RAOA

Descargas del artículo: 182

artículos leído en línea RAOA

Accesos RAOA Id: 411

artículos leído en línea RAOA

Database ID: 2023001001

Biocompatibilidad materiales bioactivos MTA osteogénesis Bioactive materials biocompatibility MTA osteogenic activity

Auspiciantes del Website:

anuncio 3 Revista de la Asociación Odontológica Argentina
anuncio 3 Revista de la Asociación Odontológica Argentina


Google académico RAOA  Schema Org RAOA

Internet Archive RAOA  Dublin Core RAOA



Revista de la Asociación Odontológica Argentina

La Revista de la Asociación Odontológica Argentina, RAOA, es la principal vía de expresión de la producción científica argentina en odontología y un vínculo de unión y medio de información para los colegas e instituciones del país y del exterior. 
Versión impresa ISSN 0004-4881
Versión electrónica ISSN 2683-7226. 
DOI: 10.52979/raoa.1898
Título abreviado: Rev Asoc Odontol Argent




Flag Counter